←All Articles
Best Incubator Thermometers and Hygrometers 2026
Gear Reviews

Best Incubator Thermometers and Hygrometers 2026

The best thermometers and hygrometers for hatching eggs, from budget incubator gauges to precision logging sensors. Verified in-stock picks and prices.

By Jonathan Caruso, FlockGuide editor18 min readPublished 2026-11-24

Researched from university extension, USDA, and veterinary sources. How we research.

A hatch lives or dies on two numbers: temperature and humidity. Run an incubator a degree too hot for 21 days and you get early, weak, or dead chicks. Let the humidity swing and the air cell never sizes right, so chicks drown in the shell or stick before they can turn. The thermometer and hygrometer are the cheapest insurance you will buy for a hatch, and the readout built into most incubators is the one thing you should not trust.

Our top pick for most hatchers: IncuTherm Plus Digital Thermometer and Hygrometer. A remote probe you set at egg height, min/max memory, and both numbers on one screen. Around $29.

Best for accuracy and logging: SensorPush HT.w. A lab-grade sensor that records every reading to your phone so you can see the overnight dips you would otherwise miss. Around $70.

We keep chickens and we have run enough hatches to know where they go wrong. Below are the thermometers and hygrometers worth putting in your incubator, checked for stock and price before this went up, with an honest note on who each one is for.

Quick Answer: Best Incubator Thermometers and Hygrometers

NeedPickPrice
Best overall for hatchingIncuTherm Plus~$29
Best accuracy and data loggingSensorPush HT.w~$70
Best WiFi phone alertsGovee H5179 WiFi~$30
Running several incubatorsGoveeLife 5-in-1 3-Pack~$63
Cheapest logging sensorGovee H5074 Bluetooth~$11
Cheapest in-incubator gaugeIncuTherm~$16

What You'll Learn

How We Picked

We cared about three things, in this order. First, accuracy where it counts: a sensor that reads within a degree and a few points of humidity across the incubation range of roughly 99 to 102°F and 40 to 75% relative humidity. A device that is accurate in a living room but drifts at hatching temperature is useless to you. Second, probe placement: the best readings come from a sensor you can position right at the top of the eggs, not stuck to the floor of the tray or baking against the heating element. Third, value at each tier, because a first-time hatcher with one tabletop incubator and a breeder running three machines need different tools.

We confirmed every product link below is in stock and points to the exact item described before publishing. Gear listings change often, and a "best of" list is only useful when the links actually work. Where a price is mentioned in the text it is a recent ballpark; the live Check Price button carries the current number.

No paid placements and no free units in exchange for ranking. These are the gauges we would buy with our own money to protect a tray of eggs.

Why Your Incubator's Built-In Readout Isn't Enough

Open any backyard hatching forum after a failed hatch and the story is almost always the same: the incubator said 99.5, the hatch came early or not at all, and a cheap second thermometer later showed the machine was running two or three degrees hot. The built-in sensors on budget incubators, and even some mid-priced ones, are not calibrated to the tolerance a hatch needs. A sensor reading one degree off does not sound like much, but over 21 days that error decides whether embryos develop on schedule.

There are three reasons the factory readout lies to you. The sensor often sits near the heating element or the lid, not down among the eggs where it matters, so it reports the air temperature in a warm or cool pocket rather than the temperature the eggs actually feel. The factory calibration is a one-time guess that drifts as the unit ages. And the humidity readout on cheap incubators is frequently the least accurate part of the whole machine.

An independent thermometer and hygrometer, set at egg height and calibrated once before you start, gives you the real numbers. It is the single highest-value add-on for any incubator, from a $40 foam tabletop unit to a cabinet machine. If you are still choosing the incubator itself, our guide to the best egg incubators covers the machines these gauges go inside.

What to Look For in an Incubator Thermometer and Hygrometer

Accuracy and a stated tolerance. Look for a device that lists its accuracy, something like plus or minus 1°F and plus or minus 3 to 5% humidity. A gauge with no spec is a gauge you cannot trust. You will still calibrate it, but a tight tolerance means less to correct for.

A remote probe or a small sensor you can place. The reading you want is at the top of the eggs, at the level the embryos sit. A unit with a wired probe lets you run the sensor inside and keep the display outside the lid, so you read it without opening the incubator and dumping heat and moisture. A compact wireless sensor that fits on the egg tray works too.

Both temperature and humidity in one unit. You need both numbers, and a combined thermo-hygrometer saves space inside a crowded incubator. A few hatchers run a separate high-accuracy thermometer and a separate hygrometer, which is fine, but most people want one screen with both.

Min and max memory. Incubators swing most overnight when the room cools and when you have just opened the lid to candle or turn. A min/max display shows you the extremes you slept through, so you can catch a cold night or an overheating element before it costs you the hatch.

Logging and alerts, if you leave the house. A basic gauge is fine for an attended hatch where you glance at it every few hours. If you work away from home during the three weeks, a Bluetooth or WiFi sensor that records the whole run and pings your phone when the temperature spikes is worth the extra money. You cannot fix a problem you never saw.

Best Incubator Thermometers and Hygrometers

◆At a Glance

DeviceLogging / alertsProbe or sensorPriceBest for
IncuTherm PlusMin/max memoryRemote wired probe~$29Best overall
SensorPush HT.wFull phone loggingCompact wireless~$70Accuracy and records
Govee H5179 WiFiWiFi alerts to phoneBuilt-in sensor~$30Remote alerts
GoveeLife 5-in-1 3-PackWiFi + gateway3 sensors + probe~$63Several machines
Govee H5074Bluetooth loggingCompact wireless~$11Cheap second sensor
IncuThermMin/max memoryIn-unit, no probe~$16Cheapest gauge

◆1. IncuTherm Plus Digital Thermometer and Hygrometer: Best Overall

IncuTherm Plus Digital Thermometer and Hygrometer. Around $29

This is the gauge made for the job. Incubator Warehouse builds the IncuTherm Plus specifically for hatching, and it shows. A large display reads temperature and humidity together, there is min/max memory so you catch the overnight swings, and the key feature is the remote sensor probe: you run the probe inside at egg height and keep the display where you can read it without opening the lid. It reads in both Fahrenheit and Celsius and lists a tolerance of plus or minus 1 degree.

Why it works: The probe is the whole point. Setting the sensor right at the top of the eggs gives you the temperature the embryos actually feel, not the air near the lid. The outside display means you check your numbers a dozen times a day without ever breaking the seal, which is exactly when cheap hatches lose heat and moisture. For a first-time hatcher or anyone who wants one reliable screen, this is the pick.

One thing to know: It is still worth a one-time calibration check against a known-good thermometer and a salt test for the humidity, covered further down. The listed accuracy is good, but every sensor benefits from knowing its offset before 21 days of eggs ride on it.

◆2. SensorPush HT.w: Best for Accuracy and Logging

SensorPush HT.w Temperature and Humidity Sensor. Around $70

If you want to know what your incubator did at 3 a.m., this is the sensor. The SensorPush is a small, water-resistant Bluetooth puck that records temperature and humidity continuously and streams every reading to an app on your phone, so you get a full graph of the entire hatch rather than whatever the display happens to show when you walk by. It is built in the USA, uses a high-accuracy sensor, and also reports dewpoint and vapor-pressure deficit for the data-minded.

Why it works: Logging turns a guess into a record. A single spike while you were at work, a slow humidity creep over three days, the exact moment the room air conditioning kicked the temperature down: you see all of it on a timeline. Breeders chasing a few more points of hatch rate live by this kind of data. The tight factory accuracy also means less correction after calibration.

One thing to know: On its own it talks to your phone over Bluetooth within about a few hundred feet. To get alerts when you are away from home, you add the separate SensorPush G1 WiFi Gateway. If you only ever hatch in the next room, you may never need it, but budget for the gateway if remote alerts are the reason you are buying.

Eggs and newly hatched chicks together in an incubator on hatching day
Eggs and newly hatched chicks together in an incubator on hatching day

◆3. Govee WiFi Thermometer Hygrometer H5179: Best for Remote Alerts

Govee WiFi Thermometer Hygrometer H5179. Around $30

This one connects straight to your home WiFi, no separate hub required, and pushes an alert to your phone when temperature or humidity leaves the range you set. Govee lists incubator use right on the box, and the app keeps two years of history you can export. For about thirty dollars it is the cheapest way to get a notification on your phone while you are at the store or at work.

Why it works: Direct WiFi is the draw. Set a high and low limit for both numbers, and if the incubator drifts out of range, your phone tells you while there is still time to act. For anyone who cannot sit next to the machine for three weeks, that warning is the difference between catching a stuck heating element and finding a cooked or chilled tray.

One thing to know: It runs on 2.4GHz WiFi, like most smart sensors, so make sure your router offers that band. The sensor housing is a bit larger than a bare probe, so check that it fits your incubator with the lid closed, or sit it on the tray with the display facing the viewing window.

◆4. GoveeLife WiFi Thermometer Hygrometer 5-in-1 3-Pack: Best for Several Machines

GoveeLife WiFi Thermometer Hygrometer 5-in-1 3-Pack with Gateway. Around $63

When you are running more than one incubator, or an incubator plus a brooder plus the coop, buying three separate sensors adds up fast. This kit bundles three sensors and a WiFi gateway, each with a large LCD you can read across the room, and all three report to one app. At around sixty dollars for three monitored spots, it is the value play for anyone past a single machine.

Why it works: One app, three locations. Watch the incubator, the lockdown tray in a second machine, and the brooder you just moved the first batch into, all from your phone. The large displays mean you also get an at-a-glance read without the app. If your hatching has grown past a hobby, this covers the whole operation for less than two premium single sensors.

One thing to know: These are living-space sensors pressed into hatching duty, so calibrate each one before it goes to work, especially the humidity. Keep the gateway within WiFi range of the sensors. For the brooder half of the setup, our brooder heat plate guide and brooder setup guide cover where those chicks go next.

◆5. Govee Bluetooth Thermometer Hygrometer H5074: Best Budget Logger

Govee Bluetooth Thermometer Hygrometer H5074. Around $11

For around eleven dollars you get a tiny Bluetooth sensor that logs temperature and humidity, holds two years of data, and reaches about 260 feet to your phone. Govee markets it for greenhouses and incubators, and it is the cheapest honest way to add logging to a hatch. Buy two and you have a sensor in the incubator and a spare for the brooder.

Why it works: It is cheap enough to own several, and the logging is the feature that matters. You will not get WiFi alerts while you are across town, but you will get a full recorded history and a phone reading whenever you are home. As a low-cost second sensor to cross-check your main gauge, it earns its keep.

One thing to know: No screen on the sensor itself, so you read it through the app. It also needs your phone in Bluetooth range to pull new data, which is fine for an attended hatch but not a substitute for WiFi alerts if being away is your worry.

◆6. IncuTherm Digital Thermometer and Hygrometer: Cheapest In-Incubator Gauge

IncuTherm Digital Thermometer and Hygrometer. Around $16

This is the no-frills Incubator Warehouse gauge. It reads temperature and humidity, keeps min/max memory, switches between Fahrenheit and Celsius, and has a magnetic back and a pop-out stand. There is no remote probe: the whole unit sits inside the incubator, so you read it through the viewing window or by opening the lid. At around sixteen dollars it is the cheapest purpose-made option.

Why it works: It is simple, accurate for the price, and made for incubators rather than repurposed from a kitchen. The min/max memory alone puts it ahead of a bare dial thermometer, since it shows you the overnight extremes. For a budget tabletop hatch where you are home to watch it, it does the job.

One thing to know: Because the display lives inside, you either read it through the window or open the lid, and opening the lid is the thing good hatchers avoid. If you can swing the extra thirteen dollars, the IncuTherm Plus and its outside display and probe is the better buy. Set either one at egg height, not on the floor of the tray.

The Right Temperature and Humidity for Hatching Eggs

A good gauge only helps if you know the numbers to aim for. For chicken eggs in a forced-air incubator, the one with a fan, the target is 99.5°F (37.5°C) measured at the top of the eggs. In a still-air incubator with no fan, heat layers, so you aim a little higher, around 100.5 to 101.5°F read at the very top of the eggs, because that is where the embryos sit.

Humidity is where more hatches go sideways, and there is honest disagreement on the exact figure because it depends on your climate and your eggs. A common starting range is 45 to 55% relative humidity for the first 18 days. Keepers in dry climates sometimes run lower, a method called dry incubation, and let the air cell guide them rather than a fixed number. For the last three days, called lockdown, you raise humidity to roughly 65 to 75% so the membrane stays soft enough for the chick to turn and pip.

Here is the quick version:

StageTemperature (forced air)Relative humidity
Days 1 to 1899.5°F (37.5°C)45 to 55%
Days 19 to 21 (lockdown)99.5°F (37.5°C)65 to 75%

The surest check that your humidity is right is not the number at all but the air cell. Candling the eggs every few days shows whether the air cell is growing on schedule; too fast means your humidity is low, too slow means it is high. Our guide to candling eggs walks through reading the air cell, and the best egg candlers covers the lights that make it easy. For the whole process start to finish, see how to hatch chicken eggs.

How to Calibrate Your Thermometer and Hygrometer

Never take a new gauge at face value. Two simple tests tell you how far off it reads, and from there you just apply the offset.

The salt test for humidity. Put about half a cup of table salt in a small cup, add just enough water to make it damp like wet sand, not soupy. Set the cup and your hygrometer together inside a sealed clear container or a zip bag and leave it somewhere stable for six to eight hours. A saturated salt solution holds the air at 75% relative humidity, so a perfect hygrometer will read 75%. If yours reads 70%, it runs 5 points low, and you add 5 to whatever it shows during a hatch. Repeat for every sensor you own.

Checking the thermometer. The cleanest home check is to compare your incubator thermometer against a trusted reference held side by side at the same spot, such as a medical thermometer that reads in the right range or a second gauge you have reason to trust. Some keepers also use an ice-water slush, which sits at 32°F (0°C), to check the low end. Whatever you use, note the difference and correct for it. A gauge that reads one degree high means you set your incubator one degree higher than its true target, which is exactly how a hatch cooks.

Do this once, before the eggs go in, and write the offsets on a piece of tape stuck to the incubator. It takes an evening and saves a hatch.

Newly hatched fluffy chicks resting in a brooder after coming out of the incubator
Newly hatched fluffy chicks resting in a brooder after coming out of the incubator

Common Mistakes

Trusting the incubator's built-in display. The reason this whole article exists. Always run an independent, calibrated gauge and believe that one.

Putting the sensor on the floor of the tray. Temperature layers inside an incubator, especially still-air units. Read at the top of the eggs, where the embryos are, not on the base.

Opening the lid to check the numbers. Every time you lift the lid you dump heat and humidity and the readings crash, then overshoot as the machine recovers. A probe with an outside display, or a sensor you read through the window or on your phone, lets you leave the lid shut.

Skipping calibration. A sensor you never checked is a sensor you are guessing with. The salt test costs nothing but a few hours.

Chasing the humidity number instead of the air cell. The target range is a starting point, not gospel. Candle the eggs and let the air cell tell you whether to run wetter or drier for your climate.

Only watching during the day. Incubators swing most overnight when the house cools. Min/max memory or a logging sensor catches the dip you slept through. If you are often away, a WiFi sensor that alerts your phone is worth the small extra cost.

If a hatch still goes wrong despite good numbers, our egg problems troubleshooting guide walks through what the eggs are telling you.

Frequently Asked Questions

◆Do I really need a separate thermometer if my incubator already has one?

Yes. The built-in sensors on most budget and mid-range incubators are not calibrated tightly enough for hatching, and they often read the air near the lid or heating element rather than the temperature at egg height. A single degree of error over 21 days is enough to ruin a hatch. An independent, calibrated gauge set among the eggs is the cheapest insurance you can buy.

◆What temperature and humidity should an egg incubator be?

For chicken eggs in a forced-air incubator, aim for 99.5°F (37.5°C) at the top of the eggs. Still-air incubators run slightly higher, around 100.5 to 101.5°F read at egg top. Keep humidity around 45 to 55% for the first 18 days, then raise it to roughly 65 to 75% for the final three days of lockdown.

◆Where should I place the thermometer or probe in the incubator?

At the top of the eggs, at the height the embryos sit. Do not lay the sensor on the floor of the tray, where it reads a cooler or warmer pocket, and do not let it touch an eggshell or the heating element directly. A gauge with a wired probe makes this easy because you position just the probe inside and keep the display outside the lid.

◆How do I calibrate an incubator hygrometer?

Use the salt test. Put about half a cup of salt in a cup, dampen it with a little water, and seal it with your hygrometer in a clear container for six to eight hours. The air will settle at 75% relative humidity, so note how far your hygrometer reads from 75 and apply that offset during the hatch.

◆Is a digital or analog incubator thermometer better?

Digital, in almost every case. A digital thermometer with a probe reads faster, shows humidity on the same screen, and usually offers min/max memory to catch overnight swings. Old spirit-filled dial thermometers can work but are harder to read precisely and give you no humidity or memory.

◆Can I use a reptile, greenhouse, or room thermometer and hygrometer for hatching?

Often yes. Many sensors marketed for reptiles, greenhouses, or wine cellars use the same components and cover the incubation range of temperature and humidity. The two things that matter are that it is accurate across roughly 99 to 102°F and up to 75% humidity, and that you calibrate it first. Several picks on this list are sold for multiple uses for exactly this reason.

◆Do I need a WiFi or Bluetooth model, or is a basic gauge fine?

A basic gauge with min/max memory is fine if you are home to check it through the day. A Bluetooth or WiFi sensor earns its cost when you are away for long stretches during the three weeks: logging shows you the overnight and midday swings you missed, and WiFi alerts ping your phone the moment something drifts out of range so you can act before the hatch is lost.

◆How many thermometers should I run in one incubator?

One good calibrated gauge is enough for most backyard hatches, but many experienced hatchers run two in different spots to confirm the reading and to check for hot or cold zones, which still-air incubators are prone to. A cheap second logging sensor is an easy way to cross-check your main gauge without spending much.

◆What is dry incubation and does it change the gauge I need?

Dry incubation means running lower humidity for the first 18 days, often in the 20 to 40% range, and relying on the air cell rather than a fixed number, which suits keepers in humid climates. It does not change the gauge you need. You still want an accurate, calibrated hygrometer; you are just aiming at a different target and watching the air cell closely when you candle.

Getting temperature and humidity right is most of the battle in hatching, and a trustworthy thermometer and hygrometer is what makes it possible. Once your chicks are out, our week-by-week chick raising guide covers the brooder weeks, and new to all of this, start with our beginner's guide to raising backyard chickens.


Sources:

Want more chicken tips?

Check out our other guides or save this one for later